CVE-2024-8956
PTZOptics PT30X-SDI/NDI Cameras Authentication Bypass Vulnerability
This vulnerability is in the CISA Known Exploited Vulnerabilities catalog: attackers are using it. If you run PT30X-SDI/NDI Cameras, fix it now.
CISA required action: Apply mitigations per vendor instructions or discontinue use of the product if mitigations are unavailable.
US federal civilian agencies must remediate by Nov 25, 2024.
Patch status
No official fix confirmed yet
Until a fix ships, follow the vendor's mitigations and CISA's required action, limit exposure of affected systems, and watch this record for a patch.
Description
PTZOptics PT30X-SDI/NDI-xx before firmware 6.3.40 is vulnerable to an insufficient authentication issue. The camera does not properly enforce authentication to /cgi-bin/param.cgi when requests are sent without an HTTP Authorization header. The result is a remote and unauthenticated attacker can leak sensitive data such as usernames, password hashes, and configurations details. Additionally, the attacker can update individual configuration values or overwrite the whole file.
Source: NIST National Vulnerability Database. Official vulnerability data, reproduced as published.
Affected products
| Product | Vendor | Source |
|---|---|---|
| PT30X-SDI/NDI Cameras | PTZOptics | KEV |
Sources: KEV = CISA Known Exploited Vulnerabilities catalog. Version details have not been published yet.
Intelligence timeline
Developments from the last 30 days, newest first.
- CVSS scoredUpdateKEV
CVE-2024-8956 scored CVSS 9.1: PTZOptics PT30X-SDI/NDI Cameras, PTZOptics PT30X-SDI/NDI Cameras Authentication Bypass Vulnerability
CISA lists this as exploited in the wild. Unpatched PT30X-SDI/NDI Cameras systems are exposed to active attacks now.
Basis: NIST National Vulnerability Database
1 earlier event is available with a subscription. See plans.
Coverage